Products

MOLD LEVEL MEASURING SYSTEM

1. SLAB

2. THIN SLAB

3. BLOOM

4. BEAM BLANK



Features and Benefits

  • No dangerous radiation, no precautions for protection of health.
  • The electromagnetic sensor is fastened directly to the mold top so it does not obstruct operating personnel and/or function of a tubechanger in any way.
  • It is possible to use the MLM System signal also for automatic start of casting.
  • The mold level sensor could be assembled and fully tested on the mold in the workshop to save necessary time for mold exchange on the casting machine.
  • MLM System measures true molten steel level in the mold regardless thickness of slag or casting powder on surface of molten steel bath.
  • The system characteristic does not depend on the steel grade.

IMPORTANT CONDITIONS FOR GOOD PERFORMANCE OF THE VUHZ ELECTROMAGNETIC MOLD LEVEL MEASURING SYSTEM

  • Proper fixing of the sensor/sensors on the mold top.
  • No handling with ferromagnetic tools in proximity of sensor during automatic mold level control.
  • No splashed steel near sensing coils.
  • Sufficient flow rate of cooling water that meets technical requirements.
  • Good mechanical conditions of the sensors.
  • In case that utilizing of MEMS, FC mold or EMBR is intended then any components in the vicinity of the mold level sensor must be made of non-magnetic steel with contents of ferromagnetic phase below 1 %.